Project Builder User Interface
Ascent Xtrata Pro User's Guide
427
Regions are defined manually by drawing rectangles on the document or by
restricting the locator to specific pages. The coordinates of a region are shown in the
list at the bottom of the dialog box.
Instead of drawing a region you can click “Add” to create a new region with default
parameters. The region can then be adjusted with the mouse or by changing the
values in the list.
Figure 6-84. Bar Code Locator Properties – Regions Tab
Enable locator for
Locators can be restricted to specific pages of the document using this option. Any
regions that have been defined can be independently defined for one or more specific
pages.
All pages
This option is selected by default. That means the region settings apply to all
pages of the document. If the “All pages” option is selected, the other page
options are disabled.
First page:
If selected, the locator algorithm operates only on the first page. Make sure that
the regions are defined on the first page.